smoke developed index composite decking products

Outdoor PaperStone Products
In a fire it retains its stability for an extended time. It has a UL Class A rating for both flame spread and smoke developed index in accordance with ASTM E84 testing. PaperStone Panels are Available in Sizes to Meet Specific Appli ion Requirements Maximum panel size is 5 x 12 feet.

Get Price

FLAME AND SMOKE RATING Engineers Pestan North America
602.2 Combustibles within Ducts or Plenums Materials exposed within ducts or plenums shall be noncombustible or shall have a flame spread index not greater than twenty five 25 and a smoke developed index not greater than fifty 50 when tested as a composite product in accordance with ASTM E 84 or UL 723 except as indi ed below.

Get Price

DCA1 Flame Spread Performance of Wood Products Used for .
A smoke-developed index was also measured for some of the wood products listed in Table 1 and Table 2. This index also has a value of approximately 100 for the wood calibrant.None of the products tested and presented in this document have a smoke-developed index exceeding the code-specified limit of 450.

Get Price

ASTM E 84 Standard test method for surface burning .
materials. The flame spread Index and Smoke Developed Index values obtained by the ASTM E 84 test are used by code officials and regulatory agencies in the acceptance of interior finish materials for various appli ions. The most widely accepted classifi ion system is

Get Price

Flame Spread - an overview ScienceDirect Topics
Flame spread index and smoke developed index material test data are reported on the basis of calibration procedure which sets each index of cement board and red oak wood at 0 and 100 respectively. This test has been widely adopted for use by the building code authorities to regulate the use of interior finish materials.

Get Price

Seven Trust Building Products Inc. Cellular PVC Fabri ions .
For decking and porch flooring installations ensure surfaces are suitable for installation of decking and that adequate structural support has been provided. 1. Standard Installation: Confirm that joists are spaced at 16 inches on center maximum and are sloped at a minimum of 1/4 inch per foot away from the building.

Get Price

Radiant Barrier ASTM e84 Fire Test w/ e2599 RadiantGUARD
smoke developed index - characteristic of a material to emit smoke when exposed to flame or fire. The flame spread index and smoke developed index values obtained by the ASTM E84 test are used by code officials and regulatory agencies such as IRC IECC IBC in the acceptance of interior finish materials for various appli ions.

Get Price

Flame Spread - The Canadian Wood Council - CWC
Appendix D-3 of the NBC Division B provides information related to generic flame-spread ratings and smoke developed classifi ions of a variety of building materials. Information is only provided for generic materials for which extensive fire test data is available refer to Table 1 below . For instance lumber regardless of species and .

Get Price

IntuPaper expanding your options in fire protection - Forfyre
The Flame Spread Index FSI and Smoke Developed Index SDI are measured as part of the testing and form key criteria in the classifi ion of materials Availability and possible convertions IntuPaper is available in many thickesses from 0.5 mm up to 5 mm.

Get Price

Wahoo Decks Decking and Railing Systems Specifi ion
AridDek Waterproof Deck System requires less maintenance than wood or composite decking. Deck boards fit together in a tongue and groove configuration forcing water to run off the surface and funneling any water that does seep through the barrier into an integrated gutter channel creating a usable 100 percent dry under deck area.

Get Price

Decks in the Line of Fire Professional Deck Builder
Metal rails cable rails glass fire-retardant lumber heavy timber or a combination of these systems could all qualify Figure 8 . According to the 2006 IBC composite or plastic railing systems with a self-ignition temperature greater than 650¼F and a Smoke Developed Index not greater than 450 should also fly.

Get Price

International Building Code: Meeting requirements for .
The test panel produced almost no smoke and posted a remarkable flame spread index FSI of 20 and a smoke developed index SDI of 125 a vast improvement over a typical composite part. The use of this approach for composite building and construction elements should help FRP materials gain wider acceptance with architects and engineers.

Get Price

Class A Flame Spread-Rated Vintage Collection Seven Trust
SKOKIE IL—Introduced in January 2015 as the game-changer in decking the Seven Trust Deck Vintage Collection has reinvented decking yet again.Along with redefining the beauty and aesthetics of capped PVC decking Seven Trust’s Vintage Collection has now achieved a Class “A” Flame Spread Index.

Get Price

Composite Panels - TechLite
ASTM E 84 Class A – Flame Spread Index = 10 / Smoke Developed Index = 55. Fire Rating Natural ASTM E 84 Class A – Flame Spread Index = 5 / Smoke Developed Index = 20 CAN/ULC S102 – Flame Spread Index = 0 / Smoke Developed Index = 30

Get Price

PHYSICAL AND MECHANICAL PROPERTIES FOR Seven Trust TRANSCEND AND .
a Corresponding Smoke Developed Index is 300. b Values shown are for reference only. These values should not be used to calculate gapping for Seven Trust. Follow Seven Trust installation literature for proper width-to-width and end-to-end gapping information. c Material weight loss was 0%. d Ultimate strength values are not meant for design analysis.

Get Price

fireproof composite decking examples - WPC Deck Board
Heat from the deck fire for example may break the glass in a sliding floor . Smoke Developed Index of a particular composite decking before allowing its use in the. Questions about ? Find answers here - - Similar to Questions about ? Find answers here - Find answers to the most commonly asked questions about decking and railing.

Get Price

Technical Information - Seven Trust Composite Decking: The .
Smoke Developed Index ASTM E84 350 Self Ignition: ASTM D1929 741 oF 394 C Flash Ignition: ASTM D1929 729oF 387oC Coefficient of Friction: ASTMD2394 0.59/0.64 - - - - - Static Dry Parallel/Perpendicular to grain ASTMD2394 0.92/0.84 - - - - - Static Wet Parallel/Perpendicular to grain Modulus of Elasticity ASTM D7032: 100000 lbs/in2 689.5 Mpa or .

Get Price

Fire Hazard Properties C1.10 Materials and Assemblies .
This specifi ion sets out the requirements in relation to fire hazard properties of materials and assemblies used in Class 2 to 9 buildings other than floor wall and ceiling covering and linings. Specifi ion C1.10 - Clause 7 places limits on the Spread-of-Flame Index and Smoke-Developed Index for various types of buildings and lo ions .

Get Price

Cone calorimeter tests of wood composites
FRT products provided some additional information on the flame spread index and the smoke developed index obtained in the E 84 tests. Material nos. 10 and 11 are fire-rated particleboards with a Class A rating based on a flame spread index of 20 and smoke developed index of 25. Per

Get Price